Radiant Tube Skin Temperature Calculator

Estimate tube inner and outer skin temperatures using cylindrical wall conduction, an internal film and specified fouling resistance.

Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.

1. Tube and fluid conditions
2. Thermal assumptions

Not calculated. Press Calculate; editing any input clears previous results.

Calculation Results

ParameterCalculated ValueUnit
Outer surface temperature—K
Outer surface temperature—°C
Inner metal surface temperature—K
Inner metal surface temperature—°C
Temperature rise through wall—K
Temperature rise through internal film—K
Temperature rise through fouling—K
Wall thermal resistance for active length—K/W
Wall resistance per unit length—m·K/W
Absorbed heat per unit length—W/m
Absorbed heat for active length—W

Input Summary

ParameterInput Value
Outside diameter (m)0.1
Inside diameter (m)0.08
Active tube length (m)1
Bulk fluid temperature (K)300
Absorbed outside heat flux (kW/m²)1
Constant wall thermal conductivity (W/(m·K))10
Internal film coefficient (W/(m²·K))100
Inside-area fouling resistance (m²·K/W)0

Method and formulas

q′ = qoπDo; R′wall = ln(Do/Di)/(2πk); Rwall = R′wall/L.

Ti = Tbulk + q′[1/(hiπDi) + Rfi/(πDi)]; To = Ti + q′R′wall.

Assumptions and applicability

Steady one-dimensional inward heat flow with constant conductivity, uniform absorbed flux, specified film coefficient and inside-area fouling. No boiling, coke growth, circumferential peaks or temperature-dependent material properties. Calculated skin temperature is NOT the API 530 design metal temperature. Preliminary calculation only. API 560 and API 530 public scope previews provide context; this tool does not establish API compliance or replace detailed heater, mechanical or materials design.

Frequently asked questions

Is calculated skin temperature the design metal temperature?

No. API 530 design metal temperature requires separate design provisions and material assessment.

Which area is the fouling resistance based on?

The input fouling resistance is based on inside tube area; absorbed heat flux is based on outside area.

Engineering references

  1. DOE Fundamentals Handbook, Volume 2 — Heat Transfer (1992)
  2. API 560 public scope preview — fifth edition (2016); historical scope context
  3. API 530 public scope preview — seventh edition (2015); historical scope context