Finned Tube Heat Transfer Calculator
Estimate longitudinal rectangular-fin efficiency, extended surface area and preliminary convection duty.
Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.
Not calculated. Press Calculate; editing any input clears previous results.
Calculation Results
| Parameter | Calculated Value | Unit |
|---|---|---|
| Fin face and tip area per tube | — | m² |
| Exposed bare tube area | — | m² |
| Total extended surface area | — | m² |
| Fin efficiency | — | — |
| Overall surface efficiency | — | — |
| Effective heat transfer area | — | m² |
| Preliminary local duty per tube | — | W |
| Thickness Biot number | — | — |
| Fin model | — | — |
Input Summary
| Parameter | Input Value |
|---|---|
| Fin geometry model | Longitudinal rectangular |
| Tube outside diameter (m) | 0.1 |
| Active axial tube and fin length (m) | 6 |
| Longitudinal fins per tube | 8 |
| Radial fin height (m) | 0.02 |
| Fin thickness (m) | 0.002 |
| Fin thermal conductivity (W/(m·K)) | 40 |
| Supplied uniform gas film coefficient (W/(m²·K)) | 50 |
| Tube and fin-base temperature (K) | 500 |
| Local gas temperature (K) | 700 |
Method and formulas
Longitudinal rectangular fins: Af = N L(2H +t); Ab = (πDo −Nt)L. End edges are insulated; radial tips convect.
m = √(2h/(kft)); β = h/(mkf); ηf = [tanh(mH)+β]/[(1+β tanh(mH))m(H+t/2)].
Aeffective = Ab +ηfAf; ηoverall = Aeffective/(Ab+Af); Q = hAeffective(Tgas −Tbase). Require thickness Bi = ht/(2kf) ≤0.1.
Assumptions and applicability
Uniform straight longitudinal rectangular fins with perfect base contact, uniform base temperature and supplied constant h. Exact one-dimensional convective-tip solution; no axial-edge heat transfer, contact resistance or radiation. Annular, helical and serrated fins are explicitly unsupported; do not apply this efficiency to them. Fin footprints must not overlap. Gas film coefficient must be appropriate to this geometry. Preliminary engineering only; no API 560 compliance claim. Radiation, mechanical integrity, fouling evolution and detailed vendor design require separate assessment.
Frequently asked questions
Is this a complete fired heater design?
No. This is a preliminary convection-section model with the stated assumptions. It does not establish API 560 compliance.
Why do results clear when an input changes?
A previous result no longer represents the edited conditions. Press Calculate to evaluate the current inputs; Reset and Load Example restore the example.