1. Longitudinal fin geometry
2. Fin material and local conditions

Not calculated. Press Calculate; editing any input clears previous results.

Calculation Results

ParameterCalculated ValueUnit
Fin face and tip area per tube—m²
Exposed bare tube area—m²
Total extended surface area—m²
Fin efficiency——
Overall surface efficiency——
Effective heat transfer area—m²
Preliminary local duty per tube—W
Thickness Biot number——
Fin model——

Input Summary

ParameterInput Value
Fin geometry modelLongitudinal rectangular
Tube outside diameter (m)0.1
Active axial tube and fin length (m)6
Longitudinal fins per tube8
Radial fin height (m)0.02
Fin thickness (m)0.002
Fin thermal conductivity (W/(m·K))40
Supplied uniform gas film coefficient (W/(m²·K))50
Tube and fin-base temperature (K)500
Local gas temperature (K)700

Method and formulas

Longitudinal rectangular fins: Af = N L(2H +t); Ab = (πDo −Nt)L. End edges are insulated; radial tips convect.

m = √(2h/(kft)); β = h/(mkf); ηf = [tanh(mH)+β]/[(1+β tanh(mH))m(H+t/2)].

Aeffective = Ab +ηfAf; ηoverall = Aeffective/(Ab+Af); Q = hAeffective(Tgas −Tbase). Require thickness Bi = ht/(2kf) ≤0.1.

Assumptions and applicability

Uniform straight longitudinal rectangular fins with perfect base contact, uniform base temperature and supplied constant h. Exact one-dimensional convective-tip solution; no axial-edge heat transfer, contact resistance or radiation. Annular, helical and serrated fins are explicitly unsupported; do not apply this efficiency to them. Fin footprints must not overlap. Gas film coefficient must be appropriate to this geometry. Preliminary engineering only; no API 560 compliance claim. Radiation, mechanical integrity, fouling evolution and detailed vendor design require separate assessment.

Frequently asked questions

Is this a complete fired heater design?

No. This is a preliminary convection-section model with the stated assumptions. It does not establish API 560 compliance.

Why do results clear when an input changes?

A previous result no longer represents the edited conditions. Press Calculate to evaluate the current inputs; Reset and Load Example restore the example.

Engineering references

  1. Frass — Principles of Finned-Tube Heat Exchanger Design
  2. Caleb Bell ht — LMTD and extended-surface methods
  3. API 560 — public scope, sixth edition (2026)