Fired Heater Heat Duty Calculator

Thermal duty, fuel demand and transparent combustion balances for preliminary process heater assessment.

Transparent thermal screening. Calculate heat duty, fuel demand and complete-combustion balances. Pale yellow fields are editable. Property validity depends on the selected species and gas-phase applicability; this tool does not certify heater design.
A. Fluid selection and composition

Ranges: N2 300–5000 K; other supported species 200–3500 K. Mixtures use the intersection. Valid polynomial range does not establish a stable gas phase.

B. Process operating conditions
C. Fired heater efficiency and fuel

Fuel composition is always on a mole basis. Custom composition retains the displayed heating values: update them for your mixture.

D. Combustion air and flue gas

Element balances assume complete conversion to CO2 and H2O, with N2 and excess O2. Dry air contains 21% O2 / 79% N2. Results are theoretical compositions at the specified excess air, not measured operating predictions.

E. Preliminary radiant / convection allocation

No validated tube layout, tube-metal temperature, draft, pressure-part thickness or API 560 design.

Thermodynamic Properties

Select Calculate to populate this table. Input changes clear previous values.

ParameterCalculated ValueUnit
Molecular weight—kg/kmol
Inlet Cp—kJ/(kg K)
Outlet Cp—kJ/(kg K)
Effective average Cp—kJ/(kg K)
Inlet enthalpy—kJ/kg
Outlet enthalpy—kJ/kg
Inlet density—kg/m³
Outlet density—kg/m³
Enthalpy rise—kJ/kg
N2 mass fraction—kg/kg
N2 mole fraction—kmol/kmol

Bulk properties apply to the full stream. Component mass and mole fractions are dimensionless (kg/kg and kmol/kmol). Unsupported properties are unavailable for supplied-property methods.

NASA7 Cp(T) and enthalpy are evaluated at both temperatures. Ideal-gas mixtures use mole-weighted molar properties; density uses ρ = PM/(RT). Pressure drop is inlet minus outlet.

Inlet/outlet Cp, enthalpy, density, molecular weight, mass/mole fractions and effective average Cp are shown here and in the report. Unsupported outputs remain unavailable.

Heat Duty

Select Calculate to populate this table. Input changes clear previous values.

ParameterCalculated ValueUnit
Process heat duty—kW
Process heat duty—MW
Process heat duty—kJ/h
Process heat duty—kcal/h (IT)
Process heat duty—MMBtu/h (IT)
Design heat duty—kW
Design heat duty—MW
Design heat duty—kJ/h
Design heat duty—kcal/h (IT)
Design heat duty—MMBtu/h (IT)

Q = ṁ(hout − hin)
Qdesign = Q(1 + margin/100)

Calculated in kW, MW, kJ/h, kcal/h (IT) and MMBtu/h (IT). Heating only; shaft work and kinetic/potential energy changes are neglected.

Enter inputs and select Calculate. Load Example restores a nitrogen heating case. Results clear whenever an input changes.

Heat duty, fuel consumption and efficiency

This process heater calculator sizes thermal duty from an enthalpy rise. It applies a design margin, then divides by the specified thermal efficiency to estimate fuel input. Fuel input divided by the matching LHV or HHV gives fuel mass flow.

Worked engineering example

For a supplied-property stream at 1 kg/s with hin = 100 kJ/kg and hout = 500 kJ/kg, Q = 400 kW. A 10% margin gives 440 kW. At 80% LHV efficiency, firing is 550 kW. For a supplied LHV of 50,000 kJ/kg, fuel is 0.011 kg/s = 39.6 kg/h. The Load Example button instead demonstrates temperature-dependent nitrogen properties.

How are gas properties calculated?

Published NASA7 coefficients define Cp and enthalpy as functions of absolute temperature. Gas enthalpies include a formation reference; only the inlet-to-outlet difference contributes to process duty. No chemical reaction in the process stream is modeled.

Can I calculate water, steam or hydrocarbon liquid duty?

Use the supplied-enthalpy method with validated external properties. Water-vapor ideal-gas coefficients do not establish phase state or model boiling, condensation or real steam.

Is efficiency calculated from excess air?

No. Efficiency is an input on the selected LHV or HHV basis. Excess air affects theoretical air demand and flue composition. Stack losses and actual efficiency need additional validated models.

Are heat-transfer areas a final heater design?

No. Radiant area uses an assumed average flux. Optional convection area uses user temperatures and an ideal countercurrent LMTD. Neither calculation validates API 560 compliance.

References and property-data notice

Engineering unit conversions · Engineering reference library