All tools

Hollow Section Weight Calculator

Calculate pipe weight and circular, square or rectangular hollow section mass from dimensions and density.

Input Parameters

Outside dimensions and wall thickness in mm; length in metres. Density in kg/m³.

Reset clears dimensions and restores density to 7850 kg/m³ for the selected shape.

Results

Enter dimensions and press Calculate to see results.

Hollow section and pipe weight formulas

CHS / pipe: A = π/4 × [OD² − (OD − 2t)²].

SHS: A = B² − (B − 2t)².

RHS: A = H × B − (H − 2t) × (B − 2t).

OD is outside diameter; H and B are outside height and width; t is uniform wall thickness. All are in mm. Require 0 < 2t < the smallest outside dimension.

For every shape: A is metal area in mm²; mass per metre = A × ρ × 10⁻⁶ in kg/m; total mass = kg/m × length in metres. ρ is density in kg/m³ (default carbon steel: 7850). “Weight” here means mass in kg, not force.

SHS/RHS assume idealized sharp inside and outside corners and uniform thickness. Real sections have corner radii, welds and tolerances; use the relevant manufacturer’s section tables for supplied mass. These are geometry estimates, not standard section or load-capacity checks.

Using the hollow section and pipe weight calculator

Worked example: 100 mm outside diameter

For OD = 100 mm, wall thickness t = 5 mm, length L = 2 m and density ρ = 7850 kg/m³, the inside diameter is 100 − 2 × 5 = 90 mm.

The metal area is π/4 × (100² − 90²) = 1492.257 mm². Using the unrounded area, mass per metre is 11.714 kg/m and total mass is 23.428 kg, rounded to three decimal places.

Outside diameter, nominal size and schedule

OD is the physical outside diameter. NPS (Nominal Pipe Size) and DN (nominal diameter designation) are size labels, not values to enter directly as the measured OD or bore.

A schedule identifies a wall-thickness series for a given nominal size and reference standard. A schedule number alone is not a thickness in millimetres. Obtain the outside diameter and wall thickness from your specification, supplier or measurements and enter them manually. The Pipe Data Library explains how to interpret the labels and check pipe geometry.

SHS and RHS worked examples

At 7850 kg/m³, an idealized 100 × 100 × 5 mm SHS has area 100² − 90² = 1900 mm², mass per metre 14.915 kg/m and total mass 29.83 kg for 2 m.

An idealized 100 × 50 × 5 mm RHS has area 100 × 50 − 90 × 40 = 1400 mm², mass per metre 10.99 kg/m and total mass 21.98 kg for 2 m. These dimensions are examples, not named standard sections.

Hollow section and pipe weight questions

Why can SHS/RHS weight differ from standard tables?
The area subtracts a sharp-corner inner rectangle from the outer rectangle. Manufactured sections have rounded corners, welds and dimensional tolerances. Use the supplier’s published section mass for a specified product; this tool does not select standard hollow sections.
How do I calculate pipe weight per metre?
Multiply the metal cross-sectional area in mm² by density in kg/m³ and by 10⁻⁶ to obtain mass per metre in kg/m. Multiply kg/m by the pipe length in metres for total mass. Enter a length of 1 m if you want the total for one metre. In the example above, the result is 11.714 kg/m; the 2 m total is 23.428 kg, using unrounded values before display rounding.
Why does actual pipe weight differ?
Results model a straight, uniform hollow cylinder. Manufacturing tolerances, weld geometry, coatings, lining and end fittings can change the supplied mass; use supplier data or weighing when those details matter.
Can I use a different material?
Yes. Replace the default carbon-steel density with the density appropriate to your material grade and conditions. Keep density in kg/m³.
Which units should I enter?
Use millimetres for OD and wall thickness, metres for length, and kg/m³ for density. Wall thickness must be positive and less than half the OD.

Use Unit Conversions to prepare inputs in the required units.