Burner Capacity Calculator

Convert absorbed process duty to fired heat input and preliminary burner capacity with one explicit efficiency and design margin.

Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.

1. Duty and energy basis
2. Capacity allocation

Not calculated. Press Calculate; editing any input clears previous results.

Calculation Results

ParameterCalculated ValueUnit
Absorbed process duty / estimated recoverable duty—W
Required fired heat input—W
Required fired heat input—kW
Required fired heat input—MW
Required fired heat input—MMBtu/h (IT)
Burner design fired capacity—W
Burner design fired capacity—kW
Burner design fired capacity—MW
Burner design fired capacity—MMBtu/h (IT)
Design capacity per burner—W
Additional fired capacity allowance—W
Applied additional design margin—%
Operating burner quantity——
Duty and margin basis——

Input Summary

ParameterInput Value
Entered duty basisAbsorbed process duty
Required duty before additional margin (kW)1,000
Thermal efficiency on selected heating-value basis (%)80
Heating-value basisLower heating value
Additional design margin (zero if already included) (%)10
Equal operating burner quantity4

Method and formulas

Absorbed-duty mode: Qfired = Qabsorbed/η. Fired-input mode: Qfired = Qentered; efficiency is not applied a second time.

Qdesign = Qfired(1 + margin/100); Qper burner = Qdesign/N. kW = W/1000; MW = W/10⁶; MMBtu/h (IT) = W×3600/1,055,055,852.62.

Assumptions and applicability

Use matched LHV or HHV efficiency. The entered duty is before this additional margin; enter zero margin if a previous calculation already included it. Margin 0–100% is an implementation range, not a recommended design allowance. Fired mode reports recoverable absorbed duty using the supplied efficiency but does not divide the fired input again. Preliminary selection only; no API 560 compliance or vendor burner performance certification. Flame geometry, emissions, stability, controls, materials and installation design require separate assessment.

Frequently asked questions

Is this a complete or certified burner design?

No. This tool performs the stated preliminary calculation. Final selection requires qualified vendor performance, combustion controls and the applicable design review.

What happens when I change an input?

Results clear immediately. Press Calculate to evaluate current inputs. Reset and Load Example restore the illustrated input set.

Engineering references

  1. DOE / IHEA — Process Heating Sourcebook (2007)
  2. Cantera — LHV and HHV definitions
  3. API 560 — public scope, sixth edition (2026)