Flue Gas Pressure Drop Calculator

Estimate low-Mach gas bank pressure loss using ideal-gas density and a supplied, qualified per-row resistance coefficient.

Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.

1. Gas state and mass flow
2. Bank area and qualified resistance

Not calculated. Press Calculate; editing any input clears previous results.

Calculation Results

ParameterCalculated ValueUnit
Ideal-gas density—kg/m³
Frontal approach velocity—m/s
Minimum-area gas velocity—m/s
Minimum-area Reynolds number——
Total bank resistance coefficient——
Tube bank pressure drop—Pa
Additional pressure loss—Pa
Gas-side pressure drop—Pa
Preliminary required loss compensation—Pa
Equivalent pressure head—mmH₂O
Minimum-area Mach number——
Estimated outlet absolute pressure—Pa
Resistance basis——

Input Summary

ParameterInput Value
Gas mass flow rate (kg/s)5
Representative gas temperature (K)700
Gas absolute pressure (bar absolute)1.01325
Gas molecular weight (kg/kmol)29
Gas dynamic viscosity (Pa·s)3.50000e-5
Gas heat capacity ratio1.33
Bank resistance modelSupplied row coefficient
Tube outside diameter for Reynolds number (m)0.1
Tube bank frontal area (m²)4
Minimum gas free-flow area (m²)2
Tube rows in gas-flow direction6
Qualified loss coefficient per row (minimum-area velocity)0.5
Additional loss coefficient (same velocity basis)1
Coefficient minimum validated Reynolds number1,000
Coefficient maximum validated Reynolds number100,000

Method and formulas

ρ = PM/(8314.46261815324 T), with M in kg/kmol. vmin = ṁ/(ρAmin); ReD = ρvminDo/μ.

Kbank = Nrows·Krow; ΔPbank = Kbank ρvmin²/2; ΔPtotal = (Kbank + Kadditional)ρvmin²/2. Equivalent mmH₂O = ΔP/9.80665.

Assumptions and applicability

Resistance-coefficient model, not an automatic tube-bank correlation. Krow and its Reynolds interval must come from qualified vendor/test data for the actual bank geometry, spacing, finning and velocity convention; example values are illustrative, not design recommendations. Automatic mode is rejected. Require positive free area below frontal area, Re within the supplied interval, Mach <0.3 and ΔP ≤10% of inlet pressure. No stack buoyancy, fan curve, acceleration, soot or compressible integration. Preliminary engineering only; no API 560 compliance claim. Radiation, mechanical integrity, fouling evolution and detailed vendor design require separate assessment.

Frequently asked questions

Is this a complete fired heater design?

No. This is a preliminary convection-section model with the stated assumptions. It does not establish API 560 compliance.

Why do results clear when an input changes?

A previous result no longer represents the edited conditions. Press Calculate to evaluate the current inputs; Reset and Load Example restore the example.

Engineering references

  1. DOE Fundamentals Handbook, Volume 3 — Fluid Flow (1992)
  2. Caleb Bell ht — tube-bank methods and limitations
  3. API 560 — public scope, sixth edition (2026)