Flue Gas Pressure Drop Calculator
Estimate low-Mach gas bank pressure loss using ideal-gas density and a supplied, qualified per-row resistance coefficient.
Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.
Not calculated. Press Calculate; editing any input clears previous results.
Calculation Results
| Parameter | Calculated Value | Unit |
|---|---|---|
| Ideal-gas density | — | kg/m³ |
| Frontal approach velocity | — | m/s |
| Minimum-area gas velocity | — | m/s |
| Minimum-area Reynolds number | — | — |
| Total bank resistance coefficient | — | — |
| Tube bank pressure drop | — | Pa |
| Additional pressure loss | — | Pa |
| Gas-side pressure drop | — | Pa |
| Preliminary required loss compensation | — | Pa |
| Equivalent pressure head | — | mmH₂O |
| Minimum-area Mach number | — | — |
| Estimated outlet absolute pressure | — | Pa |
| Resistance basis | — | — |
Input Summary
| Parameter | Input Value |
|---|---|
| Gas mass flow rate (kg/s) | 5 |
| Representative gas temperature (K) | 700 |
| Gas absolute pressure (bar absolute) | 1.01325 |
| Gas molecular weight (kg/kmol) | 29 |
| Gas dynamic viscosity (Pa·s) | 3.50000e-5 |
| Gas heat capacity ratio | 1.33 |
| Bank resistance model | Supplied row coefficient |
| Tube outside diameter for Reynolds number (m) | 0.1 |
| Tube bank frontal area (m²) | 4 |
| Minimum gas free-flow area (m²) | 2 |
| Tube rows in gas-flow direction | 6 |
| Qualified loss coefficient per row (minimum-area velocity) | 0.5 |
| Additional loss coefficient (same velocity basis) | 1 |
| Coefficient minimum validated Reynolds number | 1,000 |
| Coefficient maximum validated Reynolds number | 100,000 |
Method and formulas
ρ = PM/(8314.46261815324 T), with M in kg/kmol. vmin = ṁ/(ρAmin); ReD = ρvminDo/μ.
Kbank = Nrows·Krow; ΔPbank = Kbank ρvmin²/2; ΔPtotal = (Kbank + Kadditional)ρvmin²/2. Equivalent mmH₂O = ΔP/9.80665.
Assumptions and applicability
Resistance-coefficient model, not an automatic tube-bank correlation. Krow and its Reynolds interval must come from qualified vendor/test data for the actual bank geometry, spacing, finning and velocity convention; example values are illustrative, not design recommendations. Automatic mode is rejected. Require positive free area below frontal area, Re within the supplied interval, Mach <0.3 and ΔP ≤10% of inlet pressure. No stack buoyancy, fan curve, acceleration, soot or compressible integration. Preliminary engineering only; no API 560 compliance claim. Radiation, mechanical integrity, fouling evolution and detailed vendor design require separate assessment.
Frequently asked questions
Is this a complete fired heater design?
No. This is a preliminary convection-section model with the stated assumptions. It does not establish API 560 compliance.
Why do results clear when an input changes?
A previous result no longer represents the edited conditions. Press Calculate to evaluate the current inputs; Reset and Load Example restore the example.