Radiant Heat Transfer Calculator

Estimate diffuse-gray surface radiation, heat flux and required area using emissivity, temperatures and a supplied view factor.

Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.

1. Surface temperatures and areas
2. Radiation assumptions and target

Not calculated. Press Calculate; editing any input clears previous results.

Calculation Results

ParameterCalculated ValueUnit
Net radiant heat transfer—W
Hot surface radiant flux—W/m²
Receiver radiant flux—W/m²
Effective radiating area—m²
Required hot surface area—m²
Required receiver area—m²
Temperature difference—K
Fourth-power temperature driving force—K⁴
Effective exchange factor (hot-area basis)——
Reciprocal receiver-to-hot view factor——

Input Summary

ParameterInput Value
Hot surface temperature (K)1,000
Receiver surface temperature (K)300
Hot surface area (m²)1
Receiver surface area (m²)1
Hot surface emissivity0.8
Receiver emissivity0.8
Hot-to-receiver view factor1
Required net heat transfer (kW)100

Method and formulas

Q = σ(T₁⁴ − T₂⁴) / [(1 − ε₁)/(A₁ε₁) + 1/(A₁F₁₂) + (1 − ε₂)/(A₂ε₂)]

Aeffective = 1 / total radiation resistance; q₁ = Q/A₁; q₂ = Q/A₂.

Required areas scale both supplied areas by Qtarget/Q, preserving their ratio and view factor. σ = 5.670374419 × 10⁻⁸ W/(m²·K⁴).

Assumptions and applicability

Isothermal diffuse-gray two-surface radiation network with nonparticipating intervening medium and no additional net exchange branches. Supply a physically valid two-surface enclosure/view-factor model; reciprocity alone does not prove geometry. Required-area scaling assumes the view factor remains unchanged. No flame or gas-band radiation. Preliminary calculation only. API 560 and API 530 public scope previews provide context; this tool does not establish API compliance or replace detailed heater, mechanical or materials design.

Frequently asked questions

Does this model include combustion-gas radiation?

No. It evaluates a specified surface radiation network. Use the gas radiation tool only within its separately stated limits.

How do emissivity and temperature affect duty?

Emissivity and view factor reduce the effective area; absolute temperatures enter through their fourth powers.

Engineering references

  1. DOE Fundamentals Handbook, Volume 2 — Heat Transfer (1992)
  2. Purdue Heat Transfer equation sheet — surface and space radiation resistance
  3. NIST CODATA — Stefan–Boltzmann constant
  4. API 560 public scope preview — fifth edition (2016); historical scope context
  5. API 530 public scope preview — seventh edition (2015); historical scope context