Radiant Heat Transfer Calculator
Estimate diffuse-gray surface radiation, heat flux and required area using emissivity, temperatures and a supplied view factor.
Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.
Not calculated. Press Calculate; editing any input clears previous results.
Calculation Results
| Parameter | Calculated Value | Unit |
|---|---|---|
| Net radiant heat transfer | — | W |
| Hot surface radiant flux | — | W/m² |
| Receiver radiant flux | — | W/m² |
| Effective radiating area | — | m² |
| Required hot surface area | — | m² |
| Required receiver area | — | m² |
| Temperature difference | — | K |
| Fourth-power temperature driving force | — | K⁴ |
| Effective exchange factor (hot-area basis) | — | — |
| Reciprocal receiver-to-hot view factor | — | — |
Input Summary
| Parameter | Input Value |
|---|---|
| Hot surface temperature (K) | 1,000 |
| Receiver surface temperature (K) | 300 |
| Hot surface area (m²) | 1 |
| Receiver surface area (m²) | 1 |
| Hot surface emissivity | 0.8 |
| Receiver emissivity | 0.8 |
| Hot-to-receiver view factor | 1 |
| Required net heat transfer (kW) | 100 |
Method and formulas
Q = σ(T₁⁴ − T₂⁴) / [(1 − ε₁)/(A₁ε₁) + 1/(A₁F₁₂) + (1 − ε₂)/(A₂ε₂)]
Aeffective = 1 / total radiation resistance; q₁ = Q/A₁; q₂ = Q/A₂.
Required areas scale both supplied areas by Qtarget/Q, preserving their ratio and view factor. σ = 5.670374419 × 10⁻⁸ W/(m²·K⁴).
Assumptions and applicability
Isothermal diffuse-gray two-surface radiation network with nonparticipating intervening medium and no additional net exchange branches. Supply a physically valid two-surface enclosure/view-factor model; reciprocity alone does not prove geometry. Required-area scaling assumes the view factor remains unchanged. No flame or gas-band radiation. Preliminary calculation only. API 560 and API 530 public scope previews provide context; this tool does not establish API compliance or replace detailed heater, mechanical or materials design.
Frequently asked questions
Does this model include combustion-gas radiation?
No. It evaluates a specified surface radiation network. Use the gas radiation tool only within its separately stated limits.
How do emissivity and temperature affect duty?
Emissivity and view factor reduce the effective area; absolute temperatures enter through their fourth powers.
Engineering references
- DOE Fundamentals Handbook, Volume 2 — Heat Transfer (1992)
- Purdue Heat Transfer equation sheet — surface and space radiation resistance
- NIST CODATA — Stefan–Boltzmann constant
- API 560 public scope preview — fifth edition (2016); historical scope context
- API 530 public scope preview — seventh edition (2015); historical scope context