Convection Heat Transfer Calculator
Estimate a local convection coefficient, duty, flux and required area for a single cylinder or smooth internal tube.
Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.
Not calculated. Press Calculate; editing any input clears previous results.
Calculation Results
| Parameter | Calculated Value | Unit |
|---|---|---|
| Reynolds number | — | — |
| Prandtl number | — | — |
| Nusselt number | — | — |
| Local film coefficient | — | W/(m²·K) |
| Local convective heat flux | — | W/m² |
| Local convective heat duty | — | W |
| Required local film area | — | m² |
| Overall coefficient on outside area | — | W/(m²·K) |
| Exchanger LMTD | — | K |
| Model scope | — | — |
Input Summary
| Parameter | Input Value |
|---|---|
| Heat transfer geometry | Single cylinder crossflow |
| Fluid density (kg/m³) | 0.6 |
| Fluid velocity (m/s) | 10 |
| Correlation diameter (outside for crossflow; inside for internal) (m) | 0.1 |
| Dynamic viscosity (Pa·s) | 3.00000e-5 |
| Specific heat capacity (J/(kg·K)) | 1,100 |
| Fluid thermal conductivity (W/(m·K)) | 0.05 |
| Developed flow length (internal mode) (m) | 10 |
| Local hot-side temperature (K) | 800 |
| Local cold-side temperature (K) | 500 |
| Surface area on correlation diameter (m²) | 10 |
| Target convective duty (kW) | 100 |
| Opposite inside film coefficient (external mode) (W/(m²·K)) | 1,000 |
| Tube wall thickness (external mode) (m) | 0.005 |
| Wall thermal conductivity (W/(m·K)) | 40 |
| Combined outside-area fouling resistance (m²·K/W) | 0 |
Method and formulas
Re = ρvD/μ; Pr = Cpμ/k; h = Nu·k/D; q″ = h(Th − Tc); Q = q″A; Arequired = Qtarget/q″.
External isolated cylinder: Churchill–Bernstein, with Re·Pr ≥ 0.4. Internal smooth tube: Gnielinski with f = (0.79 ln Re − 1.64)⁻²; 4000 ≤ Re ≤5×10⁶, 0.5 < Pr ≤2000, L/D ≥60.
External mode only: 1/Uo = 1/ho + Rfo + Do ln(Do/Di)/(2kw) + Do/(Di hi). Local duty uses the selected film coefficient, not Uo. LMTD is unavailable without exchanger terminal temperatures; use Performance for a specified-outlet balance.
Assumptions and applicability
External mode is a single isolated bare cylinder, not a tube-bank correlation. Supply film-temperature properties for external mode and representative bulk properties for internal mode. Forced convection only; fully developed smooth internal flow; no developing, rough, boiling or condensing flow. Uo assumes cylindrical wall and outside-area combined fouling. Preliminary engineering only; no API 560 compliance claim. Radiation, mechanical integrity, fouling evolution and detailed vendor design require separate assessment.
Frequently asked questions
Is this a complete fired heater design?
No. This is a preliminary convection-section model with the stated assumptions. It does not establish API 560 compliance.
Why do results clear when an input changes?
A previous result no longer represents the edited conditions. Press Calculate to evaluate the current inputs; Reset and Load Example restore the example.