Convection Heat Transfer Calculator

Estimate a local convection coefficient, duty, flux and required area for a single cylinder or smooth internal tube.

Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.

1. Flow geometry and film properties
2. Local temperature difference and surface

Not calculated. Press Calculate; editing any input clears previous results.

Calculation Results

ParameterCalculated ValueUnit
Reynolds number——
Prandtl number——
Nusselt number——
Local film coefficient—W/(m²·K)
Local convective heat flux—W/m²
Local convective heat duty—W
Required local film area—m²
Overall coefficient on outside area—W/(m²·K)
Exchanger LMTD—K
Model scope——

Input Summary

ParameterInput Value
Heat transfer geometrySingle cylinder crossflow
Fluid density (kg/m³)0.6
Fluid velocity (m/s)10
Correlation diameter (outside for crossflow; inside for internal) (m)0.1
Dynamic viscosity (Pa·s)3.00000e-5
Specific heat capacity (J/(kg·K))1,100
Fluid thermal conductivity (W/(m·K))0.05
Developed flow length (internal mode) (m)10
Local hot-side temperature (K)800
Local cold-side temperature (K)500
Surface area on correlation diameter (m²)10
Target convective duty (kW)100
Opposite inside film coefficient (external mode) (W/(m²·K))1,000
Tube wall thickness (external mode) (m)0.005
Wall thermal conductivity (W/(m·K))40
Combined outside-area fouling resistance (m²·K/W)0

Method and formulas

Re = ρvD/μ; Pr = Cpμ/k; h = Nu·k/D; q″ = h(Th − Tc); Q = q″A; Arequired = Qtarget/q″.

External isolated cylinder: Churchill–Bernstein, with Re·Pr ≥ 0.4. Internal smooth tube: Gnielinski with f = (0.79 ln Re − 1.64)⁻²; 4000 ≤ Re ≤5×10⁶, 0.5 < Pr ≤2000, L/D ≥60.

External mode only: 1/Uo = 1/ho + Rfo + Do ln(Do/Di)/(2kw) + Do/(Di hi). Local duty uses the selected film coefficient, not Uo. LMTD is unavailable without exchanger terminal temperatures; use Performance for a specified-outlet balance.

Assumptions and applicability

External mode is a single isolated bare cylinder, not a tube-bank correlation. Supply film-temperature properties for external mode and representative bulk properties for internal mode. Forced convection only; fully developed smooth internal flow; no developing, rough, boiling or condensing flow. Uo assumes cylindrical wall and outside-area combined fouling. Preliminary engineering only; no API 560 compliance claim. Radiation, mechanical integrity, fouling evolution and detailed vendor design require separate assessment.

Frequently asked questions

Is this a complete fired heater design?

No. This is a preliminary convection-section model with the stated assumptions. It does not establish API 560 compliance.

Why do results clear when an input changes?

A previous result no longer represents the edited conditions. Press Calculate to evaluate the current inputs; Reset and Load Example restore the example.

Engineering references

  1. Caleb Bell ht — external convection correlations
  2. Caleb Bell ht — internal convection correlations
  3. Caleb Bell ht — LMTD and extended-surface methods
  4. API 560 — public scope, sixth edition (2026)