Convection Tube Bank Sizing Calculator
Size a preliminary plain-tube inline bank from duty, supplied overall coefficient and corrected mean temperature difference.
Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.
Not calculated. Press Calculate; editing any input clears previous results.
Calculation Results
| Parameter | Calculated Value | Unit |
|---|---|---|
| Tube quantity | — | — |
| Tube rows | — | — |
| Columns per full row | — | — |
| Unused positions in last row | — | — |
| Tube outside diameter | — | m |
| Tube inside diameter | — | m |
| Transverse pitch | — | m |
| Longitudinal pitch | — | m |
| Active length per tube | — | m |
| Required outside area | — | m² |
| Installed effective plain-tube area | — | m² |
| Duty at supplied U and temperature difference | — | W |
| Arrangement | — | — |
Input Summary
| Parameter | Input Value |
|---|---|
| Sizing mode | Solve tube count |
| Required duty (kW) | 500 |
| Supplied overall coefficient on outside area (W/(m²·K)) | 50 |
| Corrected mean temperature difference (F × LMTD) (K difference) | 200 |
| Tube outside diameter (m) | 0.1 |
| Tube wall thickness (m) | 0.005 |
| Selected active tube length (count mode) (m) | 10 |
| Selected tube quantity (length mode) | 20 |
| Rows in gas-flow direction | 4 |
| Transverse centre-to-centre pitch (m) | 0.2 |
| Longitudinal centre-to-centre pitch (m) | 0.2 |
Method and formulas
Arequired = Q/(Uo·F·LMTD). Count mode: N = ceil[Arequired/(πDoL)]. Length mode: L = Arequired/(NπDo).
Di = Do − 2t; Ainstalled = NπDoL; columns = ceil(N/rows). Pitches must exceed Do; rows cannot exceed N.
Assumptions and applicability
Plain bare tubes, full circumference exposure and active straight length only. User supplies appropriate Uo and corrected mean temperature difference. No automatic crossflow correction, fin credit, fouling prediction, supports, headers or mechanical sizing. Preliminary engineering only; no API 560 compliance claim. Radiation, mechanical integrity, fouling evolution and detailed vendor design require separate assessment.
Frequently asked questions
Is this a complete fired heater design?
No. This is a preliminary convection-section model with the stated assumptions. It does not establish API 560 compliance.
Why do results clear when an input changes?
A previous result no longer represents the edited conditions. Press Calculate to evaluate the current inputs; Reset and Load Example restore the example.