Fuel Consumption Calculator
Calculate fuel mass flow and qualified-state volumetric flow from fired heat input and a consistently selected LHV or HHV.
Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.
Not calculated. Press Calculate; editing any input clears previous results.
Calculation Results
| Parameter | Calculated Value | Unit |
|---|---|---|
| Fuel mass flow | — | kg/s |
| Fuel mass flow | — | kg/h |
| Fuel mass flow | — | lb/h |
| Fuel density at specified state | — | kg/m³ |
| Fuel volumetric flow at specified state | — | m³/s |
| Fuel volumetric flow at specified state | — | m³/h |
| Fuel energy input on selected basis | — | W |
| Fuel energy balance residual | — | W |
| Heating value and volume basis | — | — |
Input Summary
| Parameter | Input Value |
|---|---|
| Required fired input (already includes any design margin) (kW) | 1,000 |
| Fired input and heating-value basis | Lower heating value |
| Heating value on selected basis (kJ/kg) | 50,000 |
| Volumetric property model | Single-phase gas |
| Gas volume reference temperature (K) | 288.15 |
| Gas volume reference absolute pressure (bar absolute) | 1.01325 |
| Gas molecular weight (kg/kmol) | 16.043 |
| Qualified gas compressibility factor | 1 |
| Supplied fuel density (density mode) (kg/m³) | 800 |
Method and formulas
ṁfuel = Qfired/HV; energy input = ṁfuel HV. No additional efficiency or design margin is applied here.
Gas: ρ = PM/(Z×8314.46261815324×T), M in kg/kmol. Qualified-density mode uses the supplied density. V̇ = ṁ/ρ.
Assumptions and applicability
HV must match the stated LHV/HHV fired-input basis. There is no automatic LHV-to-HHV conversion. Gas volume is at the explicitly entered temperature, absolute pressure and Z, not an unspecified normal/standard condition. Density mode supports a qualified liquid or gas density. Gas Z 0.2–2 is an implementation guard; phase equilibrium, flash, gas properties and heating value are not predicted. Preliminary selection only; no API 560 compliance or vendor burner performance certification. Flame geometry, emissions, stability, controls, materials and installation design require separate assessment.
Frequently asked questions
Is this a complete or certified burner design?
No. This tool performs the stated preliminary calculation. Final selection requires qualified vendor performance, combustion controls and the applicable design review.
What happens when I change an input?
Results clear immediately. Press Calculate to evaluate current inputs. Reset and Load Example restore the illustrated input set.