Convection Tube Skin Temperature Calculator
Estimate steady inner and outer tube skin temperatures from outside heat flux and cylindrical thermal resistances.
Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.
Not calculated. Press Calculate; editing any input clears previous results.
Calculation Results
| Parameter | Calculated Value | Unit |
|---|---|---|
| Inner metal surface temperature | — | K |
| Outer metal surface temperature | — | K |
| Temperature rise across tube wall | — | K |
| Tube inside diameter | — | m |
| Absorbed duty per tube | — | W |
| Inside film resistance | — | K/W |
| Inside fouling resistance | — | K/W |
| Cylindrical wall resistance | — | K/W |
| Total bulk-to-outer resistance | — | K/W |
| Temperature qualification | — | — |
Input Summary
| Parameter | Input Value |
|---|---|
| Process bulk temperature (K) | 500 |
| Absorbed outside heat flux (kW/m²) | 20 |
| Inside film coefficient (W/(m²·K)) | 1,000 |
| Inside-area fouling resistance (m²·K/W) | 2.00000e-4 |
| Tube outside diameter (m) | 0.1 |
| Tube wall thickness (m) | 0.005 |
| Active tube length (m) | 10 |
| Wall thermal conductivity (W/(m·K)) | 40 |
Method and formulas
Q = q″oπDoL; Ri = 1/(hiπDiL); Rf = Rfi/(πDiL); Rw = ln(Do/Di)/(2πkwL).
Tinner = Tbulk + Q(Ri + Rf); Touter = Tinner + QRw.
Assumptions and applicability
Steady one-dimensional radial conduction; constant conductivity and local film coefficient; nonnegative absorbed heat flux. The inner temperature is the metal/fouling interface. No circumferential peaks, coking kinetics, boiling or allowable-stress assessment. These are estimated temperatures, not code-qualified design metal temperatures. Preliminary engineering only; no API 560 compliance claim. Radiation, mechanical integrity, fouling evolution and detailed vendor design require separate assessment.
Frequently asked questions
Is this a complete fired heater design?
No. This is a preliminary convection-section model with the stated assumptions. It does not establish API 560 compliance.
Why do results clear when an input changes?
A previous result no longer represents the edited conditions. Press Calculate to evaluate the current inputs; Reset and Load Example restore the example.