Convection Section Geometry Calculator

Estimate inline plain-tube convection-section dimensions, frontal area and geometric free-flow area.

Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.

1. Inline tube bank
2. Clearances to internal boundaries

Not calculated. Press Calculate; editing any input clears previous results.

Calculation Results

ParameterCalculated ValueUnit
Internal section width—m
Internal section height—m
Internal section gas-flow depth—m
Total tube quantity——
Tube rows——
Tube columns——
Transverse pitch—m
Longitudinal pitch—m
Transverse clear gap—m
Longitudinal clear gap—m
Gross frontal area—m²
Minimum geometric free-flow area—m²
Free-to-frontal area ratio——
Internal section volume—m³
Orientation and exclusions——

Input Summary

ParameterInput Value
Tube outside diameter (m)0.1
Active tube length along section height (m)6
Rows along gas-flow depth6
Columns across section width8
Transverse centre-to-centre pitch (m)0.2
Longitudinal centre-to-centre pitch (m)0.2
Clearance at each side wall (m)0.1
Clearance at each tube end (m)0.1
Upstream clearance (m)0.3
Downstream clearance (m)0.3

Method and formulas

W = (Ncolumns −1)ST + Do +2cside; H = L +2cend; Dsection = (Nrows −1)SL + Do + cupstream + cdownstream.

Afrontal = WH; Amin = WH − NcolumnsDoL; Ntotal = NrowsNcolumns.

Assumptions and applicability

Rectangular internal enclosure, inline plain horizontal tubes, gas flow normal to tube axes along section depth. The stated width/height orientation is a bookkeeping convention. Free area includes ideal side/end bypass; it excludes support plates, fins, soot and flow maldistribution. Not a casing, refractory or structural design. Preliminary engineering only; no API 560 compliance claim. Radiation, mechanical integrity, fouling evolution and detailed vendor design require separate assessment.

Frequently asked questions

Is this a complete fired heater design?

No. This is a preliminary convection-section model with the stated assumptions. It does not establish API 560 compliance.

Why do results clear when an input changes?

A previous result no longer represents the edited conditions. Press Calculate to evaluate the current inputs; Reset and Load Example restore the example.

Engineering references

  1. DOE Fundamentals Handbook, Volume 3 — Fluid Flow (1992)
  2. API 560 — public scope, sixth edition (2026)