Process Fluid Pressure Drop Calculator

Calculate single-phase convection-coil straight-tube, return-bend and fitting pressure losses with Darcy friction.

Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.

1. Process fluid and parallel paths
2. Tube length and local losses

Not calculated. Press Calculate; editing any input clears previous results.

Calculation Results

ParameterCalculated ValueUnit
Process fluid velocity—m/s
Mass flow per path—kg/s
Reynolds number——
Darcy friction factor——
Relative roughness——
Straight tube pressure drop—Pa
Return bend loss—Pa
Other fitting loss—Pa
Total frictional pressure drop—Pa
Elevation pressure change—Pa
Total static pressure drop—Pa
Outlet absolute pressure—Pa
Inlet Mach number (gas only)——
Flow regime——

Input Summary

ParameterInput Value
Process fluid phaseSingle-phase process fluid
Total mass flow rate (kg/s)2
Equal parallel flow paths2
Representative process density (kg/m³)800
Dynamic viscosity (Pa·s)0.001
Inlet absolute pressure (bar absolute)10
Heat capacity ratio (gas mode)1.3
Tube inside diameter (m)0.05
Straight length per path (m)100
Absolute roughness (m)4.50000e-5
Return bends per path10
Loss coefficient per return bend1.5
Other fitting loss coefficient sum2
Outlet elevation above inlet (m)0

Method and formulas

v = ṁ/(NpathsρπDi²/4); Re = ρvDi/μ; fD =64/Re for Re <2300; iterative Colebrook for 4000 ≤ Re ≤10⁸.

ΔPstraight = fD(L/Di)ρv²/2; ΔPbends = NbendsKbendρv²/2; ΔPfittings = ΣKρv²/2; ΔPstatic = ΔPloss + ρgΔz.

Assumptions and applicability

Uses the unchanged verified single-phase Darcy model shared with Radiant Tube Pressure Drop. Constant representative properties, equal path flow and supplied fitting coefficients. Rejects two-phase, transitional 2300 ≤Re <4000, relative roughness >0.05, nonpositive outlet pressure; gas requires γ >1, Mach <0.3 and pressure change ≤10%. No boiling, cavitation or heated compressible acceleration. Preliminary engineering only; no API 560 compliance claim. Radiation, mechanical integrity, fouling evolution and detailed vendor design require separate assessment.

Frequently asked questions

Is this a complete fired heater design?

No. This is a preliminary convection-section model with the stated assumptions. It does not establish API 560 compliance.

Why do results clear when an input changes?

A previous result no longer represents the edited conditions. Press Calculate to evaluate the current inputs; Reset and Load Example restore the example.

Engineering references

  1. DOE Fundamentals Handbook, Volume 3 — Fluid Flow (1992)
  2. COMSOL Pipe Flow theory — Darcy–Weisbach and Colebrook equations
  3. API 560 — public scope, sixth edition (2026)