Process Fluid Pressure Drop Calculator
Calculate single-phase convection-coil straight-tube, return-bend and fitting pressure losses with Darcy friction.
Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.
Not calculated. Press Calculate; editing any input clears previous results.
Calculation Results
| Parameter | Calculated Value | Unit |
|---|---|---|
| Process fluid velocity | — | m/s |
| Mass flow per path | — | kg/s |
| Reynolds number | — | — |
| Darcy friction factor | — | — |
| Relative roughness | — | — |
| Straight tube pressure drop | — | Pa |
| Return bend loss | — | Pa |
| Other fitting loss | — | Pa |
| Total frictional pressure drop | — | Pa |
| Elevation pressure change | — | Pa |
| Total static pressure drop | — | Pa |
| Outlet absolute pressure | — | Pa |
| Inlet Mach number (gas only) | — | — |
| Flow regime | — | — |
Input Summary
| Parameter | Input Value |
|---|---|
| Process fluid phase | Single-phase process fluid |
| Total mass flow rate (kg/s) | 2 |
| Equal parallel flow paths | 2 |
| Representative process density (kg/m³) | 800 |
| Dynamic viscosity (Pa·s) | 0.001 |
| Inlet absolute pressure (bar absolute) | 10 |
| Heat capacity ratio (gas mode) | 1.3 |
| Tube inside diameter (m) | 0.05 |
| Straight length per path (m) | 100 |
| Absolute roughness (m) | 4.50000e-5 |
| Return bends per path | 10 |
| Loss coefficient per return bend | 1.5 |
| Other fitting loss coefficient sum | 2 |
| Outlet elevation above inlet (m) | 0 |
Method and formulas
v = ṁ/(NpathsρπDi²/4); Re = ρvDi/μ; fD =64/Re for Re <2300; iterative Colebrook for 4000 ≤ Re ≤10⁸.
ΔPstraight = fD(L/Di)ρv²/2; ΔPbends = NbendsKbendρv²/2; ΔPfittings = ΣKρv²/2; ΔPstatic = ΔPloss + ρgΔz.
Assumptions and applicability
Uses the unchanged verified single-phase Darcy model shared with Radiant Tube Pressure Drop. Constant representative properties, equal path flow and supplied fitting coefficients. Rejects two-phase, transitional 2300 ≤Re <4000, relative roughness >0.05, nonpositive outlet pressure; gas requires γ >1, Mach <0.3 and pressure change ≤10%. No boiling, cavitation or heated compressible acceleration. Preliminary engineering only; no API 560 compliance claim. Radiation, mechanical integrity, fouling evolution and detailed vendor design require separate assessment.