Convection Section Performance Calculator
Evaluate specified-outlet convection heat recovery using temperature-dependent flue-gas enthalpy and a process heat balance.
Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.
Not calculated. Press Calculate; editing any input clears previous results.
Calculation Results
| Parameter | Calculated Value | Unit |
|---|---|---|
| Gas sensible heat released | — | W |
| Heat lost to surroundings | — | W |
| Convection heat recovery to process | — | W |
| Gas inlet temperature | — | K |
| Specified gas outlet temperature | — | K |
| Process inlet temperature | — | K |
| Calculated process outlet temperature | — | K |
| Process temperature rise | — | K |
| Process sensible heat gain | — | W |
| Energy balance residual | — | W |
| Gas inlet specific heat capacity | — | J/(kg·K) |
| Gas outlet specific heat capacity | — | J/(kg·K) |
| Effective average gas heat capacity | — | J/(kg·K) |
| Gas mixture molecular weight | — | kg/kmol |
| Equivalent counterflow LMTD | — | K |
| Equivalent counterflow required conductance | — | W/K |
| Performance basis | — | — |
Input Summary
| Parameter | Input Value |
|---|---|
| Wet flue gas mass flow rate (kg/s) | 5 |
| Gas inlet temperature (K) | 900 |
| Specified gas outlet temperature (K) | 600 |
| Wet carbon dioxide mole fraction | 0.1 |
| Wet water vapour mole fraction | 0.1 |
| Wet oxygen mole fraction | 0.05 |
| Wet nitrogen mole fraction | 0.75 |
| Fraction of gas heat lost to surroundings | 0.02 |
| Process heating model | Single-phase process fluid |
| Process mass flow rate (kg/s) | 10 |
| Process inlet temperature (K) | 350 |
| Supplied effective average process heat capacity (J/(kg·K)) | 2,200 |
Method and formulas
Qgas = ṁgas[hin(Tin) −hout(Tout)] using the existing NASA7 ideal-gas mixture properties. Qloss = flossQgas; Qprocess = Qgas −Qloss.
Tprocess,out = Tprocess,in + Qprocess/(ṁprocess Cp,avg). Residual = Qgas −ṁprocessCp,avg(Tout −Tin) −Qloss.
ΔT1 = Tgas,in −Tprocess,out; ΔT2 = Tgas,out −Tprocess,in; LMTD = (ΔT1 −ΔT2)/ln(ΔT1/ΔT2), equal-difference limit applied. UAequivalent = Qprocess/LMTD.
Assumptions and applicability
Specified gas outlet heat balance, not a prediction of gas outlet from installed surface. Wet ideal-gas CO₂/H₂O/O₂/N₂ fractions must sum to one; conservative 400–3000 K gas range. Process uses supplied effective average Cp and must remain nonboiling single phase. Acid dew point, dissociation, reactions and condensation are excluded. Counterflow equivalent LMTD/UA is not a crossflow correction or validated exchanger rating. Preliminary engineering only; no API 560 compliance claim. Radiation, mechanical integrity, fouling evolution and detailed vendor design require separate assessment.
Frequently asked questions
Is this a complete fired heater design?
No. This is a preliminary convection-section model with the stated assumptions. It does not establish API 560 compliance.
Why do results clear when an input changes?
A previous result no longer represents the edited conditions. Press Calculate to evaluate the current inputs; Reset and Load Example restore the example.