Radiant Section Geometry Calculator

Estimate rectangular radiant enclosure dimensions, wall areas, clearances and exposed area for an inline vertical tube layout.

Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.

1. Inline vertical tube arrangement
2. Enclosure clearances

Not calculated. Press Calculate; editing any input clears previous results.

Calculation Results

ParameterCalculated ValueUnit
Total tube count——
Preliminary internal width—m
Preliminary internal depth—m
Preliminary internal height—m
Gross enclosure volume—m³
Four vertical radiant wall areas—m²
Floor area (roof equal)—m²
Total internal bounding area—m²
Total cylindrical tube outside area—m²
Total exposed tube area—m²
Approximate free gas volume—m³
Centre-to-centre tube pitch—m
Clear tube-to-tube gap—m
Outer tube surface-to-wall clearance—m
Clearance at each tube end—m
Height / width——
Width / depth——
Exposed tube area / vertical wall area——

Input Summary

ParameterInput Value
Tube rows2
Tube columns3
Tube outside diameter (m)0.1
Centre-to-centre pitch (m)0.2
Active vertical tube length (m)2
Exposed circumference fraction1
Outer tube surface-to-wall clearance (m)0.1
Clearance at each tube end (m)0.2

Method and formulas

N = rows × columns; W = (columns − 1)P + Do + 2cw; D = (rows − 1)P + Do + 2cw; H = L + 2ce.

Awall = 2H(W + D); Aenclosure = 2(WD + WH + DH); V = WDH; Atube = NπDoL.

Approximate free gas volume = WDH − NπDo²L/4 (tube outer envelope displaced).

Assumptions and applicability

Rectangular enclosure with identical vertical straight tubes on a uniform inline grid. No burner spacing, headers, refractory thickness, supports, shielding or view-factor calculation. Clearances are supplied assumptions, not API minimums. Not a complete furnace layout design. Preliminary calculation only. API 560 and API 530 public scope previews provide context; this tool does not establish API compliance or replace detailed heater, mechanical or materials design.

Frequently asked questions

Are these dimensions an approved furnace layout?

No. They describe an assumed rectangular geometric envelope requiring burner, support, access and mechanical design checks.

Does exposed area account for tube shielding?

Only the supplied exposed-circumference fraction is applied. No shielding or radiation view factors are calculated.

Engineering references

  1. DOE Fundamentals Handbook, Volume 2 — Heat Transfer (1992)
  2. API 560 public scope preview — fifth edition (2016); historical scope context
  3. API 530 public scope preview — seventh edition (2015); historical scope context