Excess Air & Oxygen Calculator

Relate excess air and dry or wet flue-gas oxygen using a complete fuel-specific combustion balance.

Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.

1. Fuel gas composition on mole basis
2. Solve direction and oxygen measurement

Not calculated. Press Calculate; editing any input clears previous results.

Calculation Results

ParameterCalculated ValueUnit
Fuel mixture molecular weight—kg/kmol
Stoichiometric oxygen requirement—kmol/s
Theoretical dry air molar flow—kmol/s
Theoretical dry air mass flow—kg/s
Actual dry air molar flow—kmol/s
Actual dry air mass flow—kg/s
Water carried by combustion air—kg/s
Actual humid air mass flow—kg/s
Dry air-to-fuel mass ratio—kg/kg
Humid air-to-fuel mass ratio—kg/kg
Dry flue gas molar flow—kmol/s
Wet flue gas molar flow—kmol/s
Wet flue gas mass flow—kg/s
Mass balance residual—kg/s
Excess dry combustion air—%
Dry flue gas carbon dioxide—mol%
Dry flue gas oxygen—mol%
Dry flue gas nitrogen—mol%
Wet flue gas carbon dioxide—mol%
Wet flue gas oxygen—mol%
Wet flue gas nitrogen—mol%
Wet flue gas water vapour—mol%
Combustion assumptions——

Input Summary

ParameterInput Value
Fuel methane mole fraction1
Fuel hydrogen mole fraction0
Fuel carbon monoxide mole fraction0
Fuel carbon dioxide mole fraction0
Fuel nitrogen mole fraction0
Fuel oxygen mole fraction0
Fuel water vapour mole fraction0
Calculation directionExcess air → oxygen
Measured oxygen basisDry flue gas
Fuel mass flow rate (kg/s)0.02
Excess dry combustion air (forward mode) (%)15
Measured flue gas oxygen (inverse mode) (mol%)3
Air humidity ratio (water / dry air) (kg/kg)0

Method and formulas

Forward mode balances the selected fuel at supplied excess air and reports both dry and wet O₂; it does not use an approximate universal oxygen formula.

Inverse mode: yO₂ = E S/(B + E D); E = yO₂ B/(S − yO₂D). E is fractional excess air; S is stoichiometric oxygen flow, B is product flow at zero excess, and D is product-flow increase per unit E on the chosen dry/wet basis. Humidity is included for wet measurements.

Assumptions and applicability

Same seven-component fuel and complete-combustion limits as Combustion Air. The selected dry/wet basis applies to inverse O₂ input; both bases are always reported. Inverse solution must be attainable and correspond to 0–500% excess air. Air leakage, sample drying errors, CO/unburned fuel and condensation invalidate inference. Humidity must be a qualified vapour ratio. Preliminary selection only; no API 560 compliance or vendor burner performance certification. Flame geometry, emissions, stability, controls, materials and installation design require separate assessment.

Frequently asked questions

Is this a complete or certified burner design?

No. This tool performs the stated preliminary calculation. Final selection requires qualified vendor performance, combustion controls and the applicable design review.

What happens when I change an input?

Results clear immediately. Press Calculate to evaluate current inputs. Reset and Load Example restore the illustrated input set.

Engineering references

  1. Faber Burner — elemental combustion stoichiometry
  2. Cantera — LHV and HHV definitions
  3. DOE / IHEA — Process Heating Sourcebook (2007)
  4. API 560 — public scope, sixth edition (2026)