Flue Gas Radiation Calculator
Screen optically thin CO₂/H₂O gas radiation using published Planck-mean absorption fits and a fixed cold background.
Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.
Not calculated. Press Calculate; editing any input clears previous results.
Calculation Results
| Parameter | Calculated Value | Unit |
|---|---|---|
| Carbon dioxide partial pressure | — | Pa |
| Water vapour partial pressure | — | Pa |
| CO₂ Planck-mean pressure coefficient | — | m⁻¹·atm⁻¹ |
| H₂O Planck-mean pressure coefficient | — | m⁻¹·atm⁻¹ |
| Mixture Planck-mean absorption coefficient | — | m⁻¹ |
| Approximate mean beam length (3.6V/A) | — | m |
| Screening optical depth (κL) | — | — |
| Optically thin equivalent gas emissivity | — | — |
| Approximate gas radiation to cold boundary | — | W |
| Average radiation to total boundary area | — | W/m² |
| Volumetric radiation loss | — | W/m³ |
| Fixed cold background temperature | — | K |
| Model applicability | — | — |
Input Summary
| Parameter | Input Value |
|---|---|
| Gas temperature (K) | 1,000 |
| Gas absolute pressure (bar absolute) | 1.01325 |
| Wet CO₂ mole fraction | 0.01 |
| Wet H₂O mole fraction | 0.02 |
| Participating gas volume (m³) | 0.01 |
| Total enclosing boundary area (m²) | 1 |
Method and formulas
Published TNF/RADCAL Planck-mean coefficients are polynomial fits in z = 1000/T. κ = pCO₂(atm) aCO₂(T) + pH₂O(atm) aH₂O(T).
L ≈ 3.6V/A; qvol ≈ 4σκ(Tg⁴ − 300⁴); Q = qvol V; εthin = 4κV/A.
This implementation reports exchange only when εthin ≤ 0.1, an application screening choice, not a published accuracy guarantee. Otherwise exchange and emissivity are Unavailable.
Assumptions and applicability
Limited optically thin, uniform CO₂/H₂O gas, 300–2500 K, with transparent remainder and fixed 300 K background. Atmospheric-pressure implementation only (1 atm ±1%). Mean beam length is an enclosure approximation, not a tube-bank correlation. No soot, CO, CH₄, reabsorption, hot-wall absorption, spectral overlap solution or general furnace emissivity. Ordinary optically thick fired heaters need WSGG, narrow-band or validated spectral transport; results are withheld outside the thin screening limit. Preliminary calculation only. API 560 and API 530 public scope previews provide context; this tool does not establish API compliance or replace detailed heater, mechanical or materials design.
Frequently asked questions
Can this calculate radiation in a typical optically thick heater?
No. Exchange is withheld when the optically thin screen fails. A spectral or validated weighted-gas solver is needed for reabsorption and hot walls.
Is gas emissivity a gray surface input?
No. The displayed equivalent emissivity is derived from the limited participating-gas emission model, composition and enclosure volume-to-area ratio.
Engineering references
- TNF Workshop — Optically Thin Radiation Model and Planck-mean fits
- NIST — Planck-mean absorption and radiation modelling
- Published engineering reference 3 — https://doi.org/10.1002/fld.2498
- API 560 public scope preview — fifth edition (2016); historical scope context
- API 530 public scope preview — seventh edition (2015); historical scope context