Bridgewall Temperature Calculator

Estimate radiant-section outlet gas temperature from a supplied inlet state and heat removal using temperature-dependent ideal-gas properties.

Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.

1. Gas stream and heat balance
2. Wet gas mole fractions (sum to one)

Not calculated. Press Calculate; editing any input clears previous results.

Calculation Results

ParameterCalculated ValueUnit
Preliminary bridgewall gas temperature—K
Preliminary bridgewall gas temperature—°C
Inlet sensible enthalpy relative to 300 K—kJ/kg
Outlet sensible enthalpy relative to 300 K—kJ/kg
Inlet specific heat capacity—kJ/(kg·K)
Outlet specific heat capacity—kJ/(kg·K)
Wet gas molecular weight—kg/kmol
Total radiant duty and losses—W
Gas enthalpy decrease—kJ/kg
Energy balance residual—W

Input Summary

ParameterInput Value
Supplied inlet gas temperature (K)1,400
Wet flue gas mass flow (kg/s)1
Absorbed radiant heat duty (kW)500
Other heat losses (kW)0
Carbon dioxide (CO₂) mole fraction0.1
Water vapour (H₂O) mole fraction0.15
Oxygen (O₂) mole fraction0.03
Nitrogen (N₂) mole fraction0.72

Method and formulas

ṁ[h(Tin) − h(Tout)] = Qabsorbed + Qloss; numerical bisection solves Tout using NASA7 gas polynomials.

Mixture molar enthalpy is mole-fraction weighted, then divided by mixture molecular weight. Reported sensible enthalpies use a fixed 300 K datum.

Assumptions and applicability

Fixed CO₂/H₂O/O₂/N₂ wet ideal-gas composition and supplied inlet temperature. Shared NASA7 coefficients are restricted here to 300–3500 K. No predicted flame temperature, equilibrium, dissociation, soot, condensation or spatial radiation balance. Preliminary calculation only. API 560 and API 530 public scope previews provide context; this tool does not establish API compliance or replace detailed heater, mechanical or materials design.

Frequently asked questions

Does this predict flame temperature?

No. The inlet gas temperature and total heat extraction are required inputs; the tool closes a sensible-energy balance.

How are gas properties evaluated?

Temperature-dependent NASA7 ideal-gas polynomials from the existing licensed Cantera GRI30 dataset are evaluated for the specified wet composition.

Engineering references

  1. Cantera — NASA polynomial species thermodynamics
  2. Cantera property-data license and attribution
  3. API 560 public scope preview — fifth edition (2016); historical scope context
  4. API 530 public scope preview — seventh edition (2015); historical scope context