Radiant Tube Sizing Calculator

Estimate active tube length, tube count, exposed area and an inline arrangement from an assumed absorbed heat flux.

Preliminary engineering estimate. Review the model assumptions and applicability limits below before using results.

1. Duty and sizing basis
2. Tube dimensions and arrangement

Not calculated. Press Calculate; editing any input clears previous results.

Calculation Results

ParameterCalculated ValueUnit
Tube outside diameter—m
Tube inside diameter—m
Active length per tube—m
Number of tubes——
Required exposed surface area—m²
Total cylindrical outside area—m²
Total exposed tube area—m²
Actual average absorbed heat flux—W/m²
Tube centre-to-centre pitch—m
Clear tube-to-tube gap—m
Inline rows——
Inline columns——
Unused positions in final row——
Tube-bank envelope width—m
Tube-bank envelope depth—m

Input Summary

ParameterInput Value
Absorbed heat duty (kW)100
Assumed allowable absorbed heat flux (kW/m²)10
Sizing modeSolve tube count at selected active length
Exposed circumference fraction1
Specified diameter basisOutside diameter
Specified tube diameter (m)0.1
Assumed tube wall thickness (m)0.01
Selected active length (count mode) (m)10
Selected tube count (length mode)4
Tube centre-to-centre pitch (m)0.2
Inline arrangement rows1

Method and formulas

Di = Do − 2t; Arequired = Q/qallowable; Aexposed = NπDoL fexposed.

Count mode: N = ceil(Arequired/(πDoL fexposed)). Length mode: L = Arequired/(NπDo fexposed).

Columns = ceil(N/rows); bank span = (positions − 1) × pitch + Do.

Assumptions and applicability

User-supplied flux, exposure and wall thickness are design assumptions, not prescribed limits. Straight identical tubes in an inline grid; no pressure-wall sizing, corrosion allowance, creep, supports, return lengths, shielding or local flux peaks. Preliminary calculation only. API 560 and API 530 public scope previews provide context; this tool does not establish API compliance or replace detailed heater, mechanical or materials design.

Frequently asked questions

Does this calculate an API 530 wall thickness?

No. The wall thickness and allowable absorbed flux are supplied assumptions requiring independent mechanical and thermal checks.

Why is tube count rounded upward?

Count mode selects a whole number of tubes so the assumed average allowable flux is not exceeded.

Engineering references

  1. DOE Fundamentals Handbook, Volume 2 — Heat Transfer (1992)
  2. API 560 public scope preview — fifth edition (2016); historical scope context
  3. API 530 public scope preview — seventh edition (2015); historical scope context