Engineering Data Library

Steel Channel Data Library

Five manufacturer-tabulated ISMC channels: MC 75, 125, 150, 200 and 300. MC 75 has product-range dimensions and mass only; missing thickness, area and radius are not inferred. This is not a complete channel catalogue.

Verified manufacturer subset · 5 source-checked dimensional records

Search and compare steel channel data library

Source: SAIL, Structurals from SAIL, October 2023. Sectional tables state IS 808:2021 conformance; product-range entries without a row-specific standard are labelled separately. Visually checked manufacturer data, not independently certified BIS tables.

5 of 5 source-checked records

Units are stated per column. Not published means unavailable or unverified, never zero. Rows are source values; examples below are separately identified calculations. Standard editions are not inferred.
DesignationFamily/processStandard / edition statusDepth D (mm)Flange width B (mm)Web t (mm)Flange T (mm)Area (cm²)Mass (kg/m)Root radius (mm)Source / verification
MC 75ISMCSAIL October 2023 product range; row standard not stated7540Not published / unverifiedNot published / unverifiedNot published / unverified7.14Not published / unverifiedSource PDF p. 11

PDF p11 / printed p9, conventional structurals product range, MC 75 x 40

Visually source-checked catalogue record

MC 125ISMCIS 808:2021125655.38.216.613.19.5Source PDF p. 12

Printed p10, channel table

Visually source-checked catalogue record

MC 150ISMCIS 808:2021150755.7921.316.810Source PDF p. 12

Printed p10, channel table

Visually source-checked catalogue record

MC 200ISMCIS 808:2021200756.211.428.422.311Source PDF p. 12

Printed p10, channel table

Visually source-checked catalogue record

MC 300ISMCIS 808:2021300907.813.646.236.313Source PDF p. 12

Printed p10, channel table

Visually source-checked catalogue record

Understanding the dimensions

Terminology and applicability

D is overall depth, B is flange width, t is web thickness and T is flange thickness at the source reference position. Area is the complete rolled section area in cm², including details omitted by an idealized sharp-corner model. The source’s ISMC flanges are tapered.

Verified reference example

MC 200 is tabulated at 22.3 kg/m. A 6 m piece gives 22.3 × 6 = 133.8 kg, a derived length total rather than another standard table entry.

Coverage and engineering limits

  • ISLC and parallel-flange channel families remain unavailable: no edition-specific, reusable primary table was cleared in this cycle.
  • MC 100, MC 250 and MC 400 were withheld after area/mass rounding checks. No source values were corrected.
  • The source cites IS 1852:1985 for dimensional tolerances; tolerance values were not transcribed or inferred.

Frequently asked questions

Is an MC or ISMC label a channel load rating?
No. It identifies a section family/size. Capacity also depends on grade, stability, span, connections and loading.
Why can the calculator differ?
The existing Channel profile uses rectangular elements with sharp corners, not rolled taper and fillets. Use the catalogue mass for that catalogue section.
Can I substitute ISLC dimensions?
No. ISLC is a different family and is not populated here.

Sources and reuse

Checked 10 November 2026. Source attribution: SAIL, Structurals from SAIL, October 2023. Reuse terms. SAIL permits accurate reproduction with prominent attribution, excluding third-party copyrighted material. No source logos, photographs or complete brochures are redistributed. Historical records are not claims of current stock or certification.

Related tools and libraries

Open Structural Section Weight and select Channel. Enter dimensions and select the appropriate shape manually. The existing calculator remains an independent idealized calculation; it is not a standard-section lookup or strength verification.

All Engineering Data Libraries · Existing Pipe Data Library · I-Beam & H-Beam Data · Engineering Unit Conversions